GE SX TRANSISTOR CONTROL IC3645SR4U404N2 User Manual

Page 66

Advertising
background image

ADJUSTABLE FEATURES
TRANSISTOR PUMP CONTROLS

Page 66

August 1999

switch input signal is received by the control card. SL3

limit switch is a normally open switch connected to battery

negative, the switch closing enables speed limit.

Range

0% to 100% battery volts

Setting

0 to 255

Resolution

0.375 volts per set unit

Example: Setting of 50=18.75 volts

FUNCTION 52:

MODE 2 - CONTROLLED ACCELERATION

(Push CONT 5)

Same as function 48.


FUNCTION 53:

MODE 2 - SPEED LIMIT 2 (SL2)

(Push CONT 6)

Same as Function 49.

FUNCTION 54:

MODE 2 - SPEED LIMIT 3 (SL3)

(Push CONT 7)

Same as Function 50.


FUNCTION 55: NOT APPLICABLE

This function is not applicable to this type of control and

should not be adjusted.


FUNCTION 56:

MODE 3 - CONTROLLED ACCELERATION

(Push CONT 9)

Same as function 48.

FUNCTION 57:

MODE 3 - SPEED LIMIT 2 (SL2)

(Push CONT 10)

Same as Function 49.

FUNCTION 58:

MODE 3 - SPEED LIMIT 3 (SL3)

(Push CONT 11)

Same as Function 50.

FUNCTION 59: NOT APPLICABLE

This function is not applicable to this type of control and

should not be adjusted.


FUNCTION 60:

MODE 4 - CONTROLLED ACCELERATION

(Push CONT 13)

Same as function 48.

FUNCTION 61:

MODE 4 - SPEED LIMIT 2 (SL2)

(Push CONT 14)

Same as Function 49.


FUNCTION 62:

MODE 4 - SPEED LIMIT 3 (SL3)

(Push CONT 15)

Same as Function 50.





























Advertising