Msh-18nv, Muh-18nv, Model wiring diagram – MITSUBISHI ELECTRIC MSH-07NV User Manual

Page 23: Model wiring diagram indoor unit outdoor unit

Advertising
background image

23

MSH-18NV -

E3

MUH-18NV -

E3

MODEL WIRING DIAGRAM

MODEL WIRING DIAGRAM

INDOOR UNIT

OUTDOOR UNIT

CIRCUIT BREAKER

N

2

12VDC

L

50Hz

CORD

POWER

SUPPLY

~/N 220-240V

F11

NR1

1

TRANS

HIC1

12VDC

220-240V~

DSAR

BRN

GRN/YL

W

LD1

DISPLAY

P.C.BOARD

RECEIVER

P.C.BOARD

3

3

101 102

CN CN

1

TO OUTDOOR

UNIT

CONNECTING

N

BLU

GRN/YLW

MV

151

CN

5

BLU

3

BLU

ELECTRONIC CONTROL P.C BOARD

REMOTE

CONTROLLER

3

BLU

BLU

RED

2
1

F12

2

WHT

BRN

BRN

L

3

TB

CN201

CN211

121

CN

112

CN

3

4

RT11

BRN
YLW

RED

GRY
WHT

BLK

RT12

52C

IC141

C1

1

1

2

4

MF

FOR MULTI SYSTEM

TO OUTDOOR
UNIT
CONNECTING

3

111

CN

SYMBOL

TB

DSAR

HIC1

SYMBOL

NR11

RT11

RT12

IC141

52C

SYMBOL

C11

F12

F11

MF

MV

NAME

NAME

NAME

INDOOR FAN CAPACITOR

FUSE(93

:

)

FUSE(3.15A)

INDOOR FAN MOTOR

VANE MOTOR

VARISTOR

ROOM TEMPERATURE THERMISTOR

INDOOR COIL THERMISTOR

HYBRID IC

CONTACTOR

TERMINAL BLOCK

SURGE ABSORBER

DC/DC CONVERTER

CN720

52C

1

X62

21S4

CN721

MF

SR61

MC

WHT

WHT

WHT

VL

T

VL

T

COM

52C

TAB21

DSAR

ORN

WHT

WHT

RED

RED

RED

WHT

BLU

BLU

RED

BLK

CN730

C65

DEICER P.C.BOARD

RT61

F61

IC881

X62

CN711

BLK

TRANS

TAB20

BLK

R

C

C1

T

O

INDOOR UNIT

CONNECTING

GRN/YLW

12VDC

TB

220-240V~

N

2
3
4

1

4

3

2

1

BLK

BLK

CN661

NO

NR61

S

3

2

SYMBOL

X62

21S4

52C

IC881

SYMBOL

MF

NR61

RT61

SR61

TB

SYMBOL

C1

C65

DSAR

F61

MC

NAME

NAME

NAME

COMPRESSOR CAPACITOR

OUTDOOR FAN MOTOR CAPACITOR

SURGE ABSORBER

FUSE(2A)

COMPRESSOR<INNER THERMOSTAT>

OUTDOOR FAN MOTOR

VARISTOR

DEFROST THERMISTOR

SOLID STATE RELAY

TERMINAL BLOCK

REVERSING VALVE COIL RELAY

REVERSING VALVE COIL

CONTACTOR

DC/DC CONVERTER

NOTE:1. For the outdoor electric wiring refer to the outdoor unit electric wiring diagram for servicing.

2. Use copper conductors only.(For field wiring)
3. Symbols below indicate.

: Terminal block, : Connector

NOTE:1. Use copper conductors only.(For field wiring)

2. Since the indoor and outdoor unit connecting wires have polarity, connect them according to the numbers.
3. Symbols below indicate.

: Terminal block, : Connector

4. “

”show the terminals with a lock mechanism, so they cannot be removed when you pull

the lead wire.
Be sure to pull the wire by pushing the locking lever(projected part) of the terminal with a finger.

1.Slide the sleeve.

2.Pull the wire while

pushing the locking
lever.

OB207t-1qxp 25/9/97 8:52 PM Page 23

Advertising