Yes

Yes

How to check mis-wiring and serial signal error (when outdoor unit does not work)

E

1. Turn OFF power supply.
2. Turn ON power supply.
3. Press EMERGENCY OPERATION switch.

3 min. later, what self-check result is displayed on OPERATION
INDICATOR lamp on indoor unit?

1

Start

1. Turn OFF power supply and disconnect in-out connecting wire on indoor side.

2. Short-circuit between indoor terminal block

and

3. Turn ON power supply and press EMERGENCY OPERATION switch.

3

N

•Turn OFF power supply.
•Connect ON in-out connecting wire.
•Turn ON power supply.

Is there AC220~240V between outdoor terminal blocks

-

?

N

2

3 minutes later, when EMERGENCY OPERATION
switch is pressed is there DC 5V between J8 -J7
on outdoor DEICER P.C. board?

3 minutes later, when EMERGENCY OPERATION
switch is pressed and 52C relay turns on, is there
DC 10V between both ends of R601?
(By tester, the stylus is between 5 ~10V)

Replace the outdoor DEICER P.C. board.

Replace

in-out connecting wire.

3

Check and rectify fuse and varistor on out-
door DEICER P.C. board.

Replace in-out connecting wire of

and

.

N

2

Replace the indoor electronic control
P.C. board.

1 Short circuit of JPG and JPS on the

indoor electronic control P.C. board
enables self-check to be displayed in 3
seconds.

Serial signal error is indicated.
(0.5-sec.ON, 2.5-sec.OFF)

Repair wiring.

Is there in-out mis-wiring, poor contact, or wire disconnection?

3 minutes later,is there DC 20V between both ends
of R132?
( By tester, the stylus is between 0 ~ 20V. )

+

Yes

Yes

No

No

No

No

No

Yes

Mis-wiring is indicated.(0.5-sec.ON, 0.5-sec.OFF)