DISASSEMBLY INSTRUCTIONS

2. Removing the electronic control P.C. board and the

display P.C. board.

(1) Remove the front panel. (Refer to 1)
(2) Remove the screw of the electrical cover.

Remove the electrical cover.

(3) Disconnect the room temperature thermistor and the con-

nector from the indoor coil thermistor.

(4) Remove the terminal cover.

Remove the screw of the terminal block.

(5) Remove the cord clamp.
(6) Disconnect all the connectors on the electronic control P.C.

board.

(7) Remove the screw of the ground wire.
(8) Disconnect the white lead wire and the brown lead wire

from 52C relay.

(9) Remove the electronic control P.C. board and the display

P.C. board.

OPERATING PROCEDURE

PHOTOS

1. Removing the front panel

(1) Remove the screws caps of the front panel.

Remove the screws.

(2) Pull the panel down to your side slightly and unhook the

catches at the top.

Photo 1

Photo 2

Screw

Terminal block
cover

Terminal block
cover screw

Room temperature
thermistor connector

Front panel

11-1 MSH-07NV -

MSH-09NV -

MSH-12NV -

MSH-07NV -

MSH-09NV -

MSH-12NV -

INDOOR UNIT

E2

E2

E2

E1

E1

E1

NOTE:

On the wiring diagram shows the terminals with a lock mechanism, so it

cannot be removed when you pull the lead wire Be sure to pull the wire by
pushing the locking lever (projected part) of the terminal with a finger.

Slide the sleeve.

Pull the wire while pushing
the locking lever.

Cord clamp

Indoor electronic
control P.C.board

Ground wire screw