Msh-07nv, Msh-09nv, Msh-12nv – MITSUBISHI ELECTRIC MSH-07NV User Manual

Page 45: Msh-24nv - msh-18nv

Advertising
background image

45

How to modify the remote controller P.C. board

Remove batteries before modification.
The board has a print as shown below :

The P.C.board has the print “J1” and “J2”.Jumper wires are mounted to each “J1” and “J2”.Cut J1 and J2 according to the
number of indoor unit as shown in Table 1.
After modification,push the reset button.

NOTE : For remodeling, take out the

batteries at first.
After finish remodeling, put
back the batteries then
push the RESET button.

No. 1 unit

No. 2 unit

No. 3 unit

No. 4 unit

1 unit operation

No modification

2 units operation

Same as at left

Cut J1

3 units operation

Same as at left

Same as at left

Cut J2

4 units operation

Same as at left

Same as at left

Same as at left

Cut both J1 and J2

Table.1

(2)<The reset button can be located on the front side.>

MSH-07NV -

(Serial number 7000201T~)

MSH-09NV -

(Serial number 7000201T~)

MSH-12NV -

(Serial number 7000001T~)

MSH-24NV -

MSH-07NV -

MSH-09NV -

MSH-12NV -

MSH-18NV -

(Serial number 7000001T~)

MSH-24NV -

MSH-18NV -

E3

E2

E2

E2

E2

E2

E1

E1

E1

E1

NOTE : At power supply failure or installation, indoor unit deletes the memory about remote controller. When

the power supply is turned on and indoor unit receives the first signals from the remote controller, the
remote controller number is designated as the indoor unit number. Therefore at and after the second
time indoor unit accepts the remote controller of the initial setting number.
At setting - error, turn the power supply off to cancel the individual operation and then turn the power
supply on to restart the setting.

OB207t-2qxp 25/9/97 8:55 PM Page 45

Advertising
This manual is related to the following products: