65

OPERATING PROCEDURE

PHOTOS

4. Removing the outdoor fan motor

(1) Remove the screws securing the outdoor fan motor.
(2) Remove the lead clamps.
(3) Disconnect the capacitor terminal and wire of the terminal.
(4) Pull out the outdoor fan motor.

5. Removing the compressor

(1) Remove the lead clamps.
(2) Remove the screws securing the relay panel.
(3) Remove the screw securing the service port.
(4) Remove the terminal cover. (See Photo 7.)
(5) Pull out the lead from the compressor terminal.
(6) Remove the overcurrect relay.
(7) Remove the compressor nuts.
(8) Detach the suction pipe welded section and discharge pipe

welded section with a burner.

NOTE

Before using a burner, purge gas from the pipes until the pres-

sure gauge shows 0 kg/cm

2

.

Use the burner under the condition that gas can be released

even when the inner pressure rises by heat.

Photo 5

Photo 6

Photo 7

Photo 8

Photo 9

Suction pipe

Discharge pipe

Sound proof felt

Compressor nuts

Compressor

Terminal cover

Relay panel

Outdoor fan motor

Outdoor fan motor set screws

Lead
fxture