Operating procedure photos – MITSUBISHI ELECTRIC MSH-07NV User Manual

Page 63

Advertising
background image

63

OPERATING PROCEDURE

PHOTOS

3. Removing the electrical box

(1) Remove the front panel. (Refer to 1)
(2) Remove the electrical cover.
(3) Disconnect the connector of the indoor coil thermistor.
(4) Disconnect the motor connector (CN211 and CN121) and

the vane motor connector (CN151) on the electronic con-
trol P.C. board.

(5) Remove the screw of the electrical box, remove the electri-

cal box.

4. Removing the indoor fan motor and the line flow fan

(1) Remove the front panel.
(2) Remove the electrical box.
(3) Unhook the catch on the both sides of the nozzle assem-

bly.

(4) Remove the nozzle assembly.
(5) Remove the screws of the bearing support.
(6) Remove the screw of the heat exchanger unhook the

catch.

(7) Lifting the heat exchanger, remove the bearing support.
(8) Remove the motor support.
(9) Loose the screw fixing the line flow fan, remove the line

flow fan.

(10) Remove the screws of the motor band, remove the fan

motor.

Photo 4

Photo 5

Heat exchanger

screw

Catch

Bearing support
screws

Heat exchanger

Indoor fan motor

Line flow fan

Motor band

Fan
motor
screws

Photo 3

screw

screw

OB207t-3qxp 25/9/97 9:03 PM Page 63