Refrigerant system diagram 6, Msh-07nv - msh-07nv, Muh-07nv - muh-07nv – MITSUBISHI ELECTRIC MSH-07NV User Manual

Page 24: Indoor unit outdoor unit, Msh-09nv - msh-09nv, Muh-09nv - msh-09nv

Advertising
background image

24

REFRIGERANT SYSTEM DIAGRAM

6

MSH-07NV -
MSH-07NV -

E2

E1

MUH-07NV -
MUH-07NV -

E2

E1

INDOOR UNIT

OUTDOOR UNIT

Indoor
heat
exchanger

Room temperature
thermistor
RT11

(with heat insulator)

Flared connection

Flared connection

Refrigerant pipe

[

9.52

(Option)

Muffler Reversing valve

(4-way valve)

Defrost
thermistor
RT61

Accumulator

Strainer

Outdoor
heat
exchanger

Capillary tube

[

1.4x800 (2 pcs)

Capillary tube

[

1.6x750

Capillary tube

[

1.4x850

Check
valve

Strainer

Refrigerant pipe

[

6.35 Stop valve

(Option)

(with heat insulator)

Refrigerant flow in cooling

Refrigerant flow in heating

Unit:mm

Unit:mm

Stop valve
(with service
port)

Indoor coil
thermistor
RT12

MSH-09NV -
MSH-09NV -

E2

E1

MUH-09NV -
MSH-09NV -

E2

E1

INDOOR UNIT

OUTDOOR UNIT

Indoor
heat
exchanger

Room temperature
thermistor
RT11

(with heat insulator)

Flared connection

Flared connection

Refrigerant pipe

[

9.52

(Option)

Muffler Reversing valve

(4-way valve)

Defrost
thermistor
RT61

Accumulator

Strainer

Outdoor
heat
exchanger

Capillary tube

[

1.4x800 (2 pcs)

Capillary tube

[

1.6x400

Capillary tube

[

1.6x1300

Check
valve

Strainer

Refrigerant pipe

[

6.35 Stop valve

(Option)

(with heat insulator)

Reversing valve coil
(4-way valve coil)
heating ON
cooling OFF

Refrigerant flow in cooling

Refrigerant flow in heating

Stop valve
(with service
port)

Indoor coil
thermistor
RT12

Reversing valve coil
(4-way valve coil)
heating ON
cooling OFF

OB207t-1qxp 25/9/97 8:53 PM Page 24