Figure a-1, o, A-1 t, Configuration quick reference a-3 – Motorola and V.32bis User Manual

Page 125: Configuration q uick-reference

Advertising
background image

Configuration Quick Reference A-3

C

onfiguration

Q

uick-Reference

Figure A-1. The 326X Series Modem Menu Structure - Part 1 of 4

KEY

Country Specific
Option

Option Included
in Option Sets

=

=

(A)

(D)

(1-4)

(L)

(d)

(S)

(F)

(†)

Default for All Option Sets

Default for Options Not Included in Option Sets

Default for Option Set

n

(

n

=1-4)

Option Set Default for 3261, 3263, 3266, 3268 Modems

Option Set Default for 3260, 3262, 3265, 3267 Modems

Default for 326X V.32bis Modem

Default for 326X

FAST

Modem

Available with 326X

FAST

Only

=

=

=

=

(SDC) = Sync Data Compression (available for 326X

FAST-

SDC only)

For example, in the Min Rate (AT

*

MN) option,

:9600 (2,3,4L SDC) means 9600 is the default for option sets
2, 3 and 4L (models 3261

FAST

, 3263

FAST

, 3266

FAST

and 3268

FAST

) with the Sync Data Compression product.

Otherwise, the default is 300 bps for all option sets.

=

=

=

=

TEST OPT’S

Mod=V.34 Auto (A,F)

MODULATION OPT’S

Line=Dial (1,2,3,4d)

:2W Lease (4L)

:4W Lease

:V.34 Only

:V32bis Auto (A,S)

:Auto V32

:V32bis Only

:V32 Only

:V32 Uncoded

:V22bis Only

:212 Only

:103 Only

:V21 Only

Low Speed=Bell

:CCITT

Max Rate=14.4(S)/28.8† (A,F)

Auto Type=CCITT (A)

:Codex

:33.6

:31.2

:21.6†

:19.2†

:16.8†

:14.4 (A,S)

:12.0

:9600

:7200

:4800

:2400

Min Rate=300 (A)

AdaptiveRate=On (A)

Retrain=High BER

Longspace=Off (A)

Mode=Originate (1,3)

Clock=Internal (A)

:1200

:2400

:4800

:7200

:9600 (2,3,4L SDC)

:12.0

:14.4

:16.8†

:19.2†

:21.6†

:24.0†

:Off

:Answer (2,4)

:External

:Auto A in O

:External (2 SDC)

:Loopback

:Off

:Low BER

:On

Fast Call=Off (A)

:Lvl1

:Lvl2

:Lv i3 (2,3,4L SDC)

PSTN=On (A)

:Off

:550

:1800

Guard Tone=Off

AT&L

AT

*

MM

AT

*

AY

AT

*

LS

AT

*

MX

AT

*

MN

AT

*

FC

AT

*

AP

AT

*

CA

AT&X

AT

*

RT

ATY

AT

*

MD

AT&G

V.34 Asym=On

:Off

AT

*

AR

RESTORAL OPT'S

Restore=Off (1,2,3,4d)

LtoD=Low/Fast (A)

D to L=Manual (1,2,3,4d)

Hold Dialine=Off (A)

Ans Rest=LL Fail (A)

:FP Only

:FP/108.1

:FP/116

:FP/Auto (4L)

:FP/108.ACU

:FP/116.ACU

:Low/Slow

:High/Fast

:High/Slow

:15 min

:30 min

:1 hour

:2 hour

:4 hour

:1 min

:2 min

:3 min

:4 min

:5 min (4L SDC)

:Always

AT

*

RE

AT

*

DI

AT

*

LE

AT

*

HD

AT

*

AS

Data (DCE Rate) T/D?

Pressing at this

display toggles modem

between talk/data

states

Save Changes=1

:2

:3

:4

Power Up In=Old (D)

:1

:2

:3

:4

Reinit Memory?

Dial From#=1

:n

:9

View Phone#=1

:n

:9

Link Phone#=1

:n

:9

Enter Then Dial

Select Options=1

:2

:3

:4

Accept RDL=On

TEST=End Test

LAL Busy Out=On

:Off

Enter Phone#=1

:n

:9

:LAL

:RDL

:LDL

:Pattern

:LAL Pat

:RDL Pat

:Busy Out

:Retrain

:Off

S-Reg nnn=xxx

ATZ

AT&W

AT&Y

ATDS

AT

*

DS

AT

*

ND

AT&Z

AT

*

CN

AT&F

AT

*

DR

AT&T

AT&T

ATH
ATO

AT

*

LL

ATD

ATS

AT

*

LN

Auto Redial=Off (D)

:1

:n

:15

PhaseJitter=0dg

Frq Offset=0Hz

Tx Level=0dbm

Rx Level=-0dbm

Retrains 0

Echo Delay=0ms

Far Echo Lvl=0

Nr Echo Lvl=0

Phase Roll=0

Eqlzr SNR=0dB

SQ=0 EP=0%

DTE (Rate) EC Mode

EC=(Mode)DC=(Mode)

Tx Kb 0%

Rx Kb 0%

DCD RTS CTS

DSR DTR

AOP DLP ALP

DR=0 TI=0 O D

Display Modem ID

(s/w rev lvl)

ATI

AT&V

AT

*

ST

AT&V

AT

*

ST

Rx =

nnnn

Tx =

mmmm

:1200

:300

:26.4†

:28.8†

:26.4†

:24.0†

:31.2

:33.6

Note:
When you select Modulation Mode
(AT*MM), you must ensure that the
Max Rate (AT*MX) and Min Rate
(AT*MR) parameter options are within
the valid range for the mode.

Advertising
This manual is related to the following products: