Appendix c: s, Pecifications – Millennium Enterprises Net Safety MLP-A/AR User Manual

Page 27

Advertising
background image

Net Safety Monitoring Inc.

MLP-A/AR/AD-ST1400-25

22

Appendix C: S

PECIFICATIONS

S

ENSOR

S

PECIFICATIONS

C

ONTROLLER

S

PECIFICATION

SENSOR ELEMENT

Oxygen O2 (ST1400)

Operating Temperature Range

-20°C to +50°C (-4F to +122F)

%

5

2

o

t

0

n

o

i

t

c

e

t

e

D

f

o

e

g

n

a

R

5

9

T

o

t

s

d

n

o

c

e

s

5

1

<

e

m

i

T

e

s

n

o

p

s

e

R

r

a

e

y

/

s

s

o

l

l

a

n

g

i

s

f

o

%

5

<

t

f

i

r

D

n

a

p

S

)

l

e

e

t

s

s

s

e

l

n

i

a

t

s

l

a

n

o

i

t

p

o

(

m

u

n

i

m

u

l

a

d

e

t

a

o

c

r

e

d

w

o

p

/

d

e

z

i

d

o

n

A

l

a

i

r

e

t

a

M

e

r

u

s

o

l

c

n

E

Certifications

CSA and NRTL/C certified for hazardous locations. Class I, Division 1, Groups C and D.
IEC Rating Ex d IIB T6 NEMA 3R (Class 1, Zone 1, Grp IIB T6)

)

b

l

0

.

1

(

g

K

5

.

0

t

h

g

i

e

W

L

A

T

I

G

I

D

/

G

O

L

A

N

A

Y

A

L

E

R

/

G

O

L

A

N

A

G

O

L

A

N

A

M

U

I

N

N

E

L

L

I

M

Operating Temperature Range

-20°C to +50°C (-4F to +122F)

Power Consumption @ 24 V dc

Nom 68 mA / 1.63 W

Max 90 mA / 2.16 W

Nom 75 mA / 2.0 W

Max 108 mA / 2.6 W

Nominal 125 mA/3.01 W
Maximum 155mA/3.73 W

Humidity Range

0 to 99% relative humidity, non-condensing

Operating Voltage Range

10.5 to 32.0 V dc

Enclosure Material

Powder coated Copper Free Cast Aluminum (optional stainless steel)

Certifications

CSA and NRTL/C certified for hazardous locations. Class I, Division 1, Groups B, C and D. NEMA 4X.
IEC Rating Ex d IIB+H2 T5
Note: With any Type 4 enclosure (electronics only-sensor remotely mounted in Class I, Division 1 area with seals between
sensor and electronics), CSA and NRTL/C certified for hazardous locations, Class 1, Division 2, Groups A, B, C and D.

Weight

3.2 Kg (7.0 lb)

Outputs

- 4 to 20 mA - Into a maximum loop impedance of 800 Ohms at 32 V dc or 150 Ohms at 10.5 V dc. Isolated or non-isolated loop supply.

- Premium version - Form C contacts rated 5 Amps at 30 V dc / 250 V ac. Selectable energized / de-energized, latching/non-latching configurable low
and high alarms. Fault relay is factory set as energized, non-latching and cannot be modified.

Low Power Version - Form A contacts rated.2.5 Amps at 60 V ac/dc. Selectable energized / de-energized, latching/non-latching configurable low and
high alarms. Fault relay is factory set as energized, non-latching and cannot be modified.

- Digital RS 485 Modbus RTU Protocol

Advertising
This manual is related to the following products: