set system heartbeat option { on | off }
protocol [ udp | tcp ]
port-client [ 1 - 65535 ]
ip-server [

ip_address

|

dns_name

]

port-server [ 1 - 65535 ]
url-server ("

server_name

")

number [ 1 – 1073741823 ]
interval (00:00:00:20)
sleep (00:00:30:00)
contact-email ("

string

@

domain_name

")

location ("

string

"):

The hear tbeat setting is used in conjunction with the configuration ser ver to broadcast contact and
location information about your Gateway. You can specify the

protocol, port, IP-, port-, and URL-

server.

The

interval

setting specifies the broadcast update frequency. Par t of sequence control. The inter-

val is the spacing between heartbeats, in d:h:m:s.

The

contact-email

setting is a quote-enclosed text string giving an email address for the Gateway’s

administrator.

The

location

setting is a text string allowing you to specify your geographical or other location, such

as “Secaucus, NJ.”

The

number

setting is par t of the sequence control. This is the number of heartbeats to send, at

each “inter val”, before sleeping. For example, if this is 20, in the above layout, each heartbeat
sequence will send out a total 20 heartbeats, spaced at 30 second intervals, and then sleep for 30
minutes. So to have the Gateway send out packets “forever”, this number can be set ver y high. If it
is 1440 and the inter val is 1 minute, say, the hear tbeat will go out ever y minute for 1440 minutes,
or one day, before sleeping.

The

sleep

setting is par t of sequence control. This is the time to sleep before star ting another

hear tbeat sequence, in d:h:m:s.

set system ntp

option [ off | on ]:
server-address (north-america.pool.ntp.org)
alt-server-address (pool.ntp.org):
time-zone [ -12 - 12 ]
update-period (60) [ 1 - 65535 ]:

auto-daylight-savings option [ off | on ]

auto-daylight-savings override option [ off | on ]

start-year [ 0 - 99 ]
start-month [ 1 - 12 ]
start-day [ 1- 31 ]
start-hour [ 0 - 23 ]
end-year [ 0 - 99 ]
end-month [ 1 - 12 ]
end-day [ 1 - 31 ]
end-hour [ 0 - 23 ]

Specifies the NTP ser ver address, time zone, and how often the Gateway should check the time from
the NTP ser ver. The NTP

server-address and alt-server-address can be entered as DNS names as

well as IP addresses. NTP time-zone of 0 is GMT time; options are -12 through 12 (+/- 1 hour incre-
ments from GMT time).

update-period specifies how often, in minutes, the Gateway should update the