360dvs series direct vent fireplaces, Eb-1 electrical junction box connection, Remote on/off switch installation – Majestic Appliances 360DVS3 User Manual

Page 11: Alternate switch location

Advertising
background image

11

360DVS Series Direct Vent Fireplaces

10006326

FP297A

INSTA VENT FREE

UVHB26 GAS SUPPLY

7/1/98

1/2” Gas Supply

1/2” NPT X 1/2” Flare Shut-Off Valve

3/8” Flex Line

(From Valve)

FP297a

Fig. 5 Gas shutoff valve and flex connector.

When using copper or flex connector, use only ap-

proved fittings. Always provide a union when using

black iron pipe so that the gas line can be easily discon-

nected for burner or fan servicing. Refer to the gas

specification for pressure details and ratings.
Isolate or disconnect this or any other gas appli-
ance control from the gas line when pressure test-
ing.

DO NOT subject the fireplace valve to test
pressures exceeding 1/2 psi.

EB-1 Electrical Junction Box Connection

The fireplace, when installed, must be
electrically connected and grounded in ac-
cordance with local codes; in the absence
of local codes, use the current CSA C22.1

Canadian Electrical Code.

For USA installations, follow the local
codes and National Electrical Code ANSI/
NFPA No. 70.
It is strongly suggested the wiring of the
EB-1 Electrical Junction Box be carried out
by a licensed electrician.
Ensure power to the supply line has been
disconnected before commencing with this
procedure.

The EB-1 electrical junction box has been supplied
standard on this model to allow for easy connection of
the optional fan kits. (Fig. 6)
To connect the EB-1 box to the house electrical supply
follow the steps below.
1. Remove the front cover of the EB-1 box.
2. Remove the plug socket assembly from the EB-1

box.

3. Feed the supply line in from the out through the elec-

trical knockout.

4. Connect the ground wire of the supply line to the

green screw of the socket assembly.

5. Connect the white wire of the power line to the

chrome screw of the socket assembly.

6. Connect the black wire of the power supply line to

the brass screw (polarized) of the socket assembly.

FP1428

EB-1 location

Electrical

Inlet Hole

Gas Inlet

Hole

EB-1 Electrical box Depend-

ing on the specific model,

this box may be installed on

either side of the appliance.

FP1428

Fig. 6 EB-1 attachment.

Remote ON/OFF Switch Installation

Do not wire the remote ON/OFF wall switch
for this gas appliance into a 120V power
supply.

1. Thread the wiring through the holes on the end

panels of the appliance. Take care not to cut the wire
or insulation on metal edges. Route the wire to a
conveniently located receptacle box.

2. Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

3. Connect the other ends of the wire to the gas control

valve, as shown in Figure 7.

TP
TH

TP

TH

FP1429
remote switch wiring
7/05

Remote ON/OFF Switch

Gas

Control

Valve

FP1429

Fig. 7 Remote switch wiring diagram for R models.

Alternate Switch Location

The remote switch can be installed on the front or the
side of the access door. Simply mount the switch to the
bracket provided and screw the bracket to either side
of the frame, lining up the screws with the prepunched
holes. (Fig. 8)

7. Refit the socket assembly back into the electrical

box and replace the cover plate.

8. The EB-1 electrical junction box is now ready to sup-

ply power to the FK12 or FK24 fan kit, if used.

Advertising
This manual is related to the following products: