General venting, 360dvs series direct vent fireplaces, Electronic gas control valve – Majestic Appliances 360DVS3 User Manual

Page 13: Fig. 12 honeywell ignition module

Advertising
background image

13

360DVS Series Direct Vent Fireplaces

10006326

Electronic Gas Control Valve

This appliance may be fitted with a Honeywell ignition
module.
Installation of the remote ON/OFF starter switch on
electronic ignition units
(Fig. 12):
1. Thread the wiring through the holes on the side

panels of the appliance. Take care not to cut the wire
or insulation on metal edges. Route the wire to a
conveniently located receptacle box.

2. Attach the wire to the ON/OFF switch and install the

switch into the receptacle box.

3. Connect the white wire from the wall switch to the

black wire from the transformer, using an approved
wire nut. Connect the black wire from the wall switch
to the black wire running from the #6 position of the
ignition module, also using an approved wire nut.

PILOT

HONEYWELL IGNITION MODULE

ORANGE

BLUE

BLACK

WHITE

NOVA SIT 822 VALVE

HI

LO

POWER CORD

W/FEMALE SPADE

120 VAC RTN

WHITE

GREEN

BLACK

120 VAC HOT

BLACK

YELLOW

24 VAC RET

40VA TRANSFORMER

24 VAC HOT

BLACK

WHITE

WALL SWITCH

WHITE

OFF

1 2 3 5 6 8 9

MV MV/VP PV GRD 24V SENSE SPARK

24V

ORANGE

RED

GREEN

BLACK

FP1225

Fig. 12 Honeywell ignition module.

Your fireplace is approved to be vented either through
the side wall, or vertically through the roof.

Only CFM Corporation venting components, specifi-
cally approved and labeled for this fireplace, may be
used.

Venting terminals shall not be recessed into a wall or
siding.

Horizontal venting must be installed on a level plane
without an inclining or declining slope.

There must not be any obstruction such as bushes,

General Venting

garden shed, fencing, deck or utility building within 24”
(610mm) from the front of the termination hood.
Do not locate the termination hood where excessive
snow or ice buildup may occur. Be sure to check the
vent termination area after snow falls; clear it to prevent
accidental blockage of the venting system. When using
a snow blower, make sure snow is not directed toward
the vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ-
ing minimum clearances as shown on the following
page.