360 dvs series direct vent fireplaces – Majestic Appliances 360DVS3 User Manual

Page 34

Advertising
background image

34

360 DVS Series Direct Vent Fireplaces

10006326

D

E

F

FC108

SIT

regulator

conversion

10/03

OFF

PILOT

ON

FC108

Fig. 49 Replace regulator.

10. Reassemble fireplace in the reverse order, except

for the window frame assembly. Leave this off until
after unit has been checked for leaks and the gas
supply has been bled.

11. After bleeding the gas line and checking for leaks

with a soap solution, replace the window frame as-
sembly.

12. Fire up the unit. Check for flame impingement on

the logs, adjusting them as necessary.

13. Check manifold and supply pressures against the

appliance specifications.

The procedure for converting from one gas
to another is the same regardless of the
initial gas used. The only variations are
in orifice sizes and component part num-
bers. Your authorized service provider will
ensure correct parts are used.

LOH

I

HV120

Honeywell valve

conversion

9/24/02 djt

Regulator Cap

Conversion

Screw

Pressure Regu-

lator Housing

HV120

Fig. 50 Honeywell conversion screw replacement.

Honeywell Gas Control Valve (Fig. 50)
The Honeywell valve fitted to this unit is suitable for use
with LP or Natural Gas. It is converted to the required
gas application by installing a color-coded conversion
screw.
a) Using a suitable small screwdriver, lift out the cen-

tral regulator cap from the “HI/LO” knob on the valve.

b) Unscrew the exposed conversion screw.
c) Insert the new color coded conversion screw. Do

not overtighten the screw; it must be finger- tight.

d) Refit the regulator cap.
e) Mount conversion label supplied with the conver-

sion screw to the valve in a visible position.