360DVS Series Direct Vent Fireplaces

10006326

Lighting and Operating Instructions

For Fireplaces equipped with SIT822 Gas Valve (EN or EP)

A. This fireplace is equipped with an ignition device

which automatically lights the pilot. DO NOT try to

light the pilot by hand.
B. BEFORE OPERATING, smell all around the

appliance area for gas. Be sure to smell next to

the floor because some gas is heavier than the air

and will settle on the floor.
What to do if you smell gas
• Do not try to light any appliance
• Do not operate any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas suppliers

instructions.

For your safety, read the following warnings

before lighting the appliance:

1. STOP! Read the safety information above before

continuing.

2. Turn off all electrical power to the appliance.
3. This appliance is equipped with an ignition device

which automatically lights the pilot. DO NOT try to
light the pilot by hand.

4. Access the gas control by lowering the lower

access door (louvre assembly).

• If you cannot contact your gas supplier call

the Fire Department
C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not

push in or turn by hand do not try to repair it, call

a qualified service technician. Force or attempting

repair may result in a fire or explosion.
D. Do not use this appliance if any part has been

under water. Immediately call a qualified service

technician to inspect the appliance and replace

any part of the control system and any gas control

that has been under water.

1. Turn the remote switch to the “OFF” position.
2. Turn OFF all electrical power to the fireplace if

service is required.

3. Open the lower access panel.
4. Turn the shutoff valve on the flexible gas line to the

“OFF” position.

Warning: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury and loss of life.

Lighting Instructions

Turning Off the Gas to the Appliance

HI

LO

5. Turn the remote switch, if used, OFF. Turn the

wireless remote, if used, OFF.

6. Wait five (5) minutes to clear out any gas. Then

smell for gas, including near the floor. If you smell
gas STOP. Follow instructions B in the safety
warnings above. If you do not smell gas go onto the
next step.

7. Close the access door.
8. Turn ON all electrical power to the appliance.
9. Turn remote switch or wireless remote to ON.
10. If the appliance will not operate, follow the

instructions “Turning Off the Gas to the Appliance”
(below), and call your service technician or gas
supplier.

FP297A

INSTA VENT FREE

UVHB26 GAS SUPPLY

7/1/98

NOTE: Shutoff valve

is shown in “ON” position

1/2” Gas Supply

1/2” NPT x 1/2” Flare

Shut-Off Valve

3/8” Flex Line

(from valve)