5 v.35 shunt – Multi-Tech Systems FR111 User Manual

Page 34

Advertising
background image

34

3.5

V.35 Shunt

Either EIA-232D or ITU-T V.35 electrical signal interface can be selected
on the data port. Units are shipped with EIA-232D signal levels se-
lected. Use the following procedure to select V.35.

CAUTION

This procedure requires opening the unit. Like most

products of this type, this product contains components

that are sensitive to static and static discharge. Please

use your best efforts to avoid static discharge when

contacting the components inside this unit.

WARNING:

Always disconnect the power cord before opening

the enclosure to avoid any chance of electric shock.

1. Unplug the power cord.

2. The enclosure consists of two halves. Using a Phillips screwdriver,

remove the two screws from the bottom of the unit. Remove the
top half.

3. Pry the data port shunt out of its RS232 socket and insert it into the

V.35 socket.

V.35 Shunt Position

RS232 Shunt Position

Figure 3-5. Shunts

4. Carefully reassemble the unit, making sure that no foreign objects

are accidentally left inside.

6. The data port is now configured with V.35 signal levels. The cable

pin designations are shown in Appendix A. To connect to a device
equipped with a V.35 34-pin connector, you must obtain an
adapter cable. Using the signal pin designations in Appendix A,
you may make or order a cable from most any cable vendor.