Multi-Tech Systems FR111 User Manual

Page 76

Advertising
background image

76

ing, data is represented normally. With NRZI encoding, a logical one is
represented by no transition and a zero is represented by a transition at
the beginning of the bit. Most synchronous devices can be configured
for either NRZ or NRZI. If a synchronous device is not configurable, it
most likely is set to NRZ. Refer to the device’s user documentation for
the encoding method.

The CRC Preset option allows the user to specify whether the polyno-
mial used to calculate the CRC for each frame is preset to all 1s or all
0s. This option must match the synchronous device’s CRC-preset
setting. The default is All 1s.

The Inter-frame Timer option can be changed to make the MultiFRAD
wait a specified length of time between frames being transmitted on the
data port. The user can choose delay times of 2,5,10 and 15 millisec-
onds. A typical use for this parameter is to simulate transmission delays
encountered with equipment that toggles hardware signals after
transmission of each frame, like PC cards used to connect to legacy
systems. The following options can be specified for the timer: Off, 2mS,
5mS, 10mS, and 15mS. The default is off.

Advertising