OM-2221 Page 11

SECTION 3 − INSTALLATION

3-1. Specifications

Voltage

Amperage

Max Open-

RMS Amps Input at Rated Load Output, 3-Phase at

NEMA Load

Voltages and Class I Rating

AC or DC

Rated Output

Voltage

Range in

CV Mode

Amperage

Range in

CC Mode

Max. Open-

Circuit

Voltage

380/400/415 V

(50/60 Hz)

460 V

(60 Hz)

500 V

(50/60 Hz)

575 V

(60 Hz)

KVA

KW

1000 A at 44 V,

100% Duty Cycle;

25−44 V

250−1250 A

71 V

143

124

114

100

98

53

100% Duty Cycle;

1250 A at 44 V,

60% Duty Cycle

25−44 V

250−1250 A

71 V

143

(3*)

124

(3*)

114

(3*)

100

(3*)

98

(2.37*)

53

(0.95*)

*While idling

3-2. Duty Cycle and Overheating

Duty Cycle is percentage of 10 min-

utes that unit can weld at rated load

without overheating.
If unit overheats, high temperature

shutdown light turns On, thermo-

stat(s) opens, output stops, and

cooling fan runs. Wait fifteen min-

utes for unit to cool. Reduce amper-

age or duty cycle before welding.
NOTICE − Exceeding duty cycle

can damage unit and void warranty.

Overheating

0

15

A/V

OR

Reduce Duty Cycle

Minutes

duty1 4/95 − 181 560

Continuous Welding

100% Duty Cycle At 1000 Amperes

Advertising