Miller Electric 1000 User Manual

Page 28

Advertising
background image

OM-2221 Page 24

Unit B

(Second Unit)

3-17. Matching Primary Lines L1, L2, And L3 When Using Multiple AC Units

Set on AC Volts Scale

Meter Polarity Does Not Matter

Ref. 801 882-A / Ref. 801 883-B

Unit A

(First Unit)

L1

L2

L3

A
B
C
D
E
G

I

J
K
L
N
P

Terminal Strip

TE3

A
B
C
D
E
G

I

J
K
L
N
P

Terminal Strip

TE3

Input Contactor

!

Turn Off welding power

source and disconnect input

power before opening ac-

cess door.

This test must be performed on the

units that will be interconnected us-

ing the synchronizing terminal strip

TE4. This refers to the multiple unit

hook-ups shown in Sections 4-2

and 4-3.
Power On both units. Using an AC

voltmeter, measure the voltage be-

tween terminal A of terminal strip

TE3 on both units as shown.
If the measured voltage is approxi-

mately 0 (zero) volts, the primary

lines are properly phased.
If the measured voltage is approxi-

mately 53 volts, swap the input con-

ductor connections to L1 and L3 on

the primary input contactor of unit

B.
If the measured voltage is approxi-

mately 46 volts, swap L1 and L2 on

the primary input contactor of unit

B. The meter will then read either

approximately 53 volts or approxi-

mately 26 volts. If the meter reads

approximately 53 volts, swap L1

and L3. If the meter reads approxi-

mately 26 volts, swap L2 and L3.
If the measured voltage is approxi-

mately 26 volts, swap L1 and L2 on

the primary input contactor of unit

B. The meter will then read either

approximately 0 (zero) volts or

approximately 46 volts. If the meter

reads approximately 0 volts, the pri-

mary lines are properly phased. If

the meter reads approximately 46

volts, swap L1 and L2 again, and

swap L2 and L3.
When the second unit’s primary line

phase sequences are matched with

the first unit, test primary phasing

between third unit (if applicable)

and second unit. Always test and

correct phasing between following

unit and unit previous to it.