OM-2221 Page 27

4-3. Using Multiple Units: Two or More AC Arcs

!

Turn Off welding power

source and disconnect input

power before opening ac-

cess door.

!

High weld output current

hazard! Remove all metal

jewelry, such as rings and

watches, and be careful with

tools near output terminals.

High current can cause se-

vere burns from hot metal if

touched to output terminals

and unit is On. ALWAYS turn

Off welding power sources

and disconnect input power

BEFORE making weld out-

put connections.

!

ELectric Shock can kill.

Do not touch live electrical parts.
Turn off welding power sources and

disconnect input power before

making any weld output connec-

tions.
See ANSI Z49.1 and OSHA Title

29, Chapter XVII, Part 1910, Sub-

part Q (addresses at beginning of

manual).
Do not handle or come in contact

with two live electrodes at the same

time.

!

Undersized weld cables can

cause fire.

Work cable or electrode cable must

be able to carry the weld output of

the individual welding power source

(see Section 3-8).
Do not exceed duty cycle of welding

power sources.

!

If there are any questions re-

garding this procedure, con-

tact the factory before con-

necting units.

To use two or more AC arcs with

separate electrodes, make con-

nections as shown.
Set up AC output units according to

Section 4-4.

To AC Output

Electrode #1

First Unit

Connections

Second Unit (And

Following Units)

Connections

To AC Output

Electrode #2

801 882-A

Shielded Cable To

Terminal Strip TE4

To Next AC Unit

To Work

To Work