Section 6 − maintenance and troubleshooting, 1. routine maintenance, 2. fuses f1 and f2 – Miller Electric 1000 User Manual

Page 36

Advertising
background image

OM-2221 Page 32

SECTION 6 − MAINTENANCE AND TROUBLESHOOTING

.

Maintain more often
during severe conditions.

6-1. Routine Maintenance

!

Disconnect input power

before maintaining.

n = Check

Z = Change

~ = Clean

Δ

= Repair

l = Replace

* To be done by Factory Authorized Service Agent

Every

3

Months

Δ

l Cracked Cables

nl Labels

l Cracked Parts

Δ

l Cracked Cables

Every

3

Months

n

Δ

lCables And Cords

Every

3

Months

~:Weld Terminals

Every

6

Months

~:Blow out inside

6-2. Fuses F1 And F2

Ref. 801 883-B

!

Turn Off welding power

source and disconnect input

power before checking fuse.

Fuses F1 and F2 protect the 115

volt AC winding of transformer T2.

If fuse F1 or F2 opens, the welding

power source shuts down.
Remove top cover from unit to ac-

cess fuses.
1

Fuse F1

Check F1 and replace if needed,

using a fuse of the same rating.
2

Fuse F2

Check F2 and replace if needed,

using a fuse of the same rating.
Use proper tool when removing

fuses.
Reinstall top cover.

3/8 in

Tools Needed:

2

Rear of Unit

1