Section 4 − making weld output connections – Miller Electric 1000 User Manual

Page 29

Advertising
background image

OM-2221 Page 25

SECTION 4 − MAKING WELD OUTPUT CONNECTIONS

4-1. Work And Electrode Cable Connections For Single DC or AC Arcs

!

Turn Off welding power

source and disconnect input

power before opening access

door.

!

High weld output current haz-

ard! Remove all metal jewelry,

such as rings and watches,

and be careful with tools near

output terminals. High current

can cause severe burns from

hot metal if touched to output

terminals and unit is On. AL-

WAYS turn Off welding power

sources and disconnect input

power BEFORE making weld

output connections.

!

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.
Turn off welding power sources and

disconnect input power before mak-

ing any weld output connections.
See ANSI Z49.1 and OSHA Title 29,

Chapter XVII, Part 1910, Subpart Q

(addresses at beginning of manual).
Do not handle or come in contact with

two live electrodes at the same time.

!

Undersized weld cables can

cause fire.

Work cable or electrode cable must

be able to carry the weld output of the

individual welding power source (see

Section 3-8).
Do not exceed duty cycle of welding

power sources.

!

If there are any questions re-

garding this procedure, con-

tact the factory before con-

necting units.

For DC electrode positive:
Connect the proper size and number

of weld output cables (see Section

3-8) to one of the welding power

source electrode terminals.
Connect the proper size and number

of ground cables to one of the welding

power source work terminals.
For DC electrode negative:
Connect the proper size and number

of weld output cables (see Section

3-8) to one of the welding power

source work terminals.
Connect the proper size and number

of ground cables to one of the welding

power source electrode terminals.
For AC output:
Connect the proper size and number

of weld output cables (see Section

3-8) to one of the welding power

source electrode terminals.
Connect the proper size and number

of ground cables to one of the welding

power source work terminals.

Connections For

DC Electrode Positive

Or AC Output

Connections For

DC Electrode Negative

Or AC Output

801 882-A

To Electrode

To Work

To Work

To Electrode

Advertising