9. selecting ac or dc output, Ac dc – Miller Electric 1000 User Manual

Page 20

Advertising
background image

OM-2221 Page 16

3-9. Selecting AC or DC Output

!

Turn Off welding power

source and disconnect input

power before relinking unit.

Remove top of unit.
1

AC/DC Output Selection

Label (Located Inside Unit)

2

Jumper Links

Locate terminal board inside unit.

Install jumper links for desired out-

put as shown on label.

.

Securing nuts must be re-
moved to change the position

of the three jumper links at the

right of the terminal board. To

change the position of the re-

maining six jumper links, loos-

en the securing nuts only to al-

low the slotted jumper links to

be moved. Always securely re-

tighten nuts after links are

moved.

Reinstall top of unit.

!

See Safety Rules at begin-

ning of manual for special

AC concerns.

801 881-A / Ref. S-185 482

ПП

ПП

П

П

П

П

П

П

П

П

П

П

П

П

П

П

П

ПП

П

П

П

П

ПП

ПП

ПП

ПП

П

П

П

П

П

П

П

П

П

П

П

П

П

AC

DC

1

2

Tools Needed:

3/8, 11/16, 7/8 in

3-10. Terminal Strip TE3 and Remote 14 Receptacle RC7 Information

Socket

on RC7

Terminal

on TE3

Information

24 VOLTS AC

A

A

24 volts, 12 amperes, AC. Protected by circuit breaker CB2.

24 VOLTS AC

B

B

Contact closure to A completes 24 volts AC contactor control circuit.

C

C

Command reference; +10 volts DC.

REMOTE OUTPUT CONTROL

D

D

Remote control circuit common.

E

E

0 to +10 volts DC input command signal from remote control.

115 VOLTS AC

I

I

115 volts, 12 amperes AC. Protected by circuit breaker CB1.

115 VOLTS AC

J

J

Contact closure to I completes 115 volts AC contactor control circuit.

GND

K

G

K

G

Chassis common.
Circuit common for 24, 42 and 115 volts AC circuits.

42 VOLTS AC

*

L

42 volts, 12 amperes AC. Protected by circuit breaker CB3.

A/V

AMPERAGE

F

*

Current feedback; +1 volt DC per 100 amperes.

A/V

AMPERAGE

VOLTAGE

H

*

Voltage feedback; +1 volt DC per 10 output terminal volts.

REMOTE VOLTAGE SENSING

*

N

Voltage sensing signal from Work weld output terminal.

REMOTE VOLTAGE SENSING

*

P

Voltage sensing signal from Electrode weld output terminal.

* Not Used