OM-2221 Page 28

4-4. Using AC Arcs Terminal Strip TE4 Connections

!

Turn Off welding power

source and disconnect input

power before opening ac-

cess door.

!

DC output units do not re-

quire synchronization with

AC output units.

!

If there are any questions re-

garding this procedure, con-

tact the factory before con-

necting units.

1

Terminal Strip TE4

This procedure allows the AC out-

put waveforms of two or more units

to have a phase shift. Make con-

nections between terminal strip

TE4 on applicable AC output units

as shown in illustration.

.

Do not disturb factory connec-

tions to terminal strip TE4.

!

Ensure that primary input

power conductors are con-

nected to each unit in the

same sequence (L1 to L1, L2

to L2, and L3 to L3). See Sec-

tion 3-16 for information on

connecting input power. See

Section 3-17 for information

on testing for proper primary

phase sequence.

2

Lead Being Connected To

TE4

3

Securing Screw

Strip 3/8 in (10 mm) insulation off

end of lead, insert end into proper

location on TE4, and tighten appli-

cable securing screw.
Close and secure access door.

.

Connect plug as shown in Sec-
tion 4-5.

Tools Needed:

A
B
C

1

D
E

Terminal Strip TE4 Connections For Running Multiple AC Arcs

AC Waveforms

Waveform 1

Waveform 2

Phase Shift

Connections from first to second

welding power source:

terminal A to terminal E,

terminal C to terminal C

A
B
C
D
E

A
B
C
D
E

A
B
C
D
E

TE4 on first welding

power source

TE4 on second welding

power source

TE4 on third welding

power source

Repeat same connection sequence

on following welding power sources

Connections from second to third

welding power source:

terminal A to terminal E,

terminal C to terminal C

Connections from third to fourth

welding power source:

terminal A to terminal E,

terminal C to terminal C

Ref. 801 882-A

2

3

1

3/8 in

(10 mm)

.

Use two-conductor (12 to 20 gauge) with uninsulated ground,
shielded cable to make TE4 connections. Connect uninsulated

ground wire to terminal C on TE4.