Multitec – Multitech 1777.8/7-10 G3 User Manual

Page 17

Advertising
background image

Caution

Grease lubrication

Pump version V, MTC 100/125/150

(grease lubrication only)

Fig. 27

Oil lubrication with labyrinth seal

Oil lubrication with lip seal

Multitec

17

7.3.3.2 Dismantling the drive-end rolling element bearings

N.B.: The ceramic bearing installed at the non-drive end need

not be dismantled in order to remove the drive-end rolling

element bearings. If the pump is oil-lubricated, the oil must be

drained before dismantling.

- After loosening the grub screw in the coupling hub pull out

coupling half with key 940.3.

Grease lubrication (figs. 26 and 27)

- Remove joint ring (V-ring) 411.7.

- Undo bolts 901.1.

- Remove bearing cover 360.1.
Oil lubrication with lip seal (fig. 28)

- Undo screws 914.4 and pull out together with washer 550.10

and O-ring 412.12.

- Remove bearing cover 360.2.

- Pull off sleeve 520.4 with ring 500.1 (tolerance ring) and

O-ring 412.11.

Oil lubrication with labyrinth seal (fig. 29)

- Pull out labyrinth ring 423.2.

- Undo screws 914.4 and pull out together with washer 550.10

and O-ring 412.12.

- Remove bearing cover 360.2.

The rotating unit is adjusted axially by means of

spacers 551.1. When reassembling the pump

after partial dismantling (bearing or seal replacement), the

same spacer discs 551.1 must be mounted on the bearing side

to reproduce the original rotor adjustment.
When dismantling keywayed nut 920.6, all relevant positions

such as sequence and orientation of the contact face must be

marked accordingly, to ensure identical reassembly (see also

section 7.4.4).
- Undo nut 920.2 with lockwasher 931 or nut with locknut

920.6, depending on the pump size. To undo the nut, hold
onto shaft with key 940.3.

- Pull off sleeve 520.1 with rolling element bearing(s) 320.1.

(The shaft is centered in the sleeve without locking device.)

- Remove spacers 551.1, see text above.

Note:

Pump versions V, Vx, E, Ex, F, Fx of sizes 32, 50,65 do

not have a fixed bearing as this function is taken over by the

motor bearings.

On pump versions Multitec V100, 125 and 150 the fixed bearing

is located in the support lantern 342. Dismantling and

installation shall be performed in analogy with the horizontal

versions.

Fig. 26

Fig. 28

Fig. 29

Advertising