0.2 ...0.8 mm

0.2... 0.8 mm

Multitec

24

If there is no suitable torque wrench available for tightening the

shaft nuts, proceed as follows, depending on the pump version:
Self-locking nut on drive end (or non-drive end on versions

C und D)

G

Tighten the shaft nut firmly

G

Loosen the shaft nut again

G

Apply thread-locking agent to the thread (e.g. LOCTITE)

G

Moderately tighten the shaft nut

Nut with lockwasher on drive end (or non-drive end on

versions C und D)

G

Tighten the shaft nut firmly

G

Loosen the shaft nut again

G

Moderately tighten the shaft nut

G

Bend over lockwasher

Nut with locknut on drive end (or non-drive end on versions

C und D)

G

Tighten the first shaft nut firmly

G

Loosen the first shaft nut again

G

Moderately tighten the first shaft nut

G

Block the first shaft nut with a suitable tool and tighten the

locknut firmly against the first shaft nut

Nut with locknut on non-drive end (all versions except C

and D)

G

Moderately tighten the first shaft nut

G

Block the first shaft nut with a suitable tool and tighten the

locknut firmly against the first shaft nut

Fixed bearing
The fixed bearing is the coupling-side bearing at the coupling

end. Pump size 32 is equipped with deep-groove ball bearings.

The other pump sizes are fitted with angular contact ball

bearings in X arrangement (see sectional drawing).

The spacer discs 551.1 serve to position the rotor in axial

direction.
Axial adjustment of the rotor is not required. The correct axial

position of the rotor is achieved by inserting spacer discs 551.1

to a total thickness of 1.6 mm (1 x 1 mm + 3 x 0.2 mm) in bearing

housing 350.1 on the side of the bearing (or angular contact ball

bearings).

On the old versions, the rotor is axially positioned

by inserting spacer discs 551.1 on both sides of

the bearing (or angular contact ball bearings) to a total

thickness of 1.6 mm each.
Cover bolts 901.1 (or 901.8 for oil-lubricated bearings) must

be tightened in diagonally opposite sequence to the following

torques:
MTC 32/50/65 :

30 Nm

MTC 100/125/150 :

40 Nm

After installation of the bearings, the following checks shall be

made:
- Grease-lubricated bearings: Check the clearance

between cover 360.1 and bearing housing 350.1 after

having tightened bolts 901.1. There should be a clearance

between 0.2 mm and 0.8 mm. Cover 360.1 must not rest on

the bearing housing 350.1.

- Oil lubricated bearings: Check the clearance between

cover 360.2 and bearing housing 350.1 by verifying the

dimensions prior to re-assembly (if bearings or cover have

to be replaced).

Rolling element bearing sizes

Grease-lubricated bearings

Fig. 40

Pump size

Fixed bearing 320.1

Radial bearing 320.2

32

6309 ZZ C3-HT

6309 ZZ C3-HT

50

2 x 7309 BUA

6309 ZZ C3-HT

65

2 x 7309 BUA

6309 ZZ C3-HT

100

2 x 7312 BUA

6312 C3

125

2 x 7312 BUA

6312 C3

150

2 x 7315 BUA

6315 C3

Oil lubricated bearings

Fig. 41

The same rolling element bearings are installed for oil

lubrication as for grease lubrication.

Exception: Instead of bearing type 6309 ZZ C3-HT, rolling

element bearing type 6309C3 is used for oil lubrication.