Result codes, User guide – Multi-Tech Systems MT5634ZBAV User Manual

Page 84

Advertising
background image

User Guide

74

S48

decimal

7 or 128 7

Enables (7) or disables (128)
LAPM negotiation. The fol-
lowing table lists the

S36 and

S48 configuration settings for
certain types of connections.

S48=7

S48=128

LAPM or async

Async

LAPM or hangup

Do not use

LAPM, MNP, or aysnc

LAPM, MNP, or hangup

MNP or hangup

MNP or async

S36=0, 2

S36=1, 3

S36=4, 6

S36=5, 7

S89

seconds 0, 5–255 10

Sets the length of time in the
off-line command mode be-
fore the modem goes into
standby mode. A value of
zero prevents standby mode;
a value of 1–4 sets the value
to 5.

S108

decimal

0–3, 6, 7 6

Selects the 56K digital loss if
using the modem thru a PBX
line. The default value is -6
dB loss, the value used when
calling from a typical POTS
line long distance.

0 = -0 dB digital loss, no

robbed-bit signaling

1 = -3 dB PBX digital loss
2 = -2 dB digital loss
3 = -3 dB digital loss
6 = -6 dB digital loss
7 = -0 dB digital loss with

robbed-bit signaling

Register

Unit

Range

Default

Description