19 power fail detect, Smb (i, C) connector – SUPER MICRO Computer 6014H-8 User Manual

Page 55: Overheat led (joh1), Glan1/2 (ethernet ports)

Advertising
background image

Chapter 5: Advanced Serverboard Setup

5-19

Power Fail Detect

Connect a cable from your power

supply to the Power Fail header

(JP9) to provide warning of power

supply failure. This warning sig-

n a l i s p a s s e d t h r o u g h t h e

PWR_LED pin to indicate on the

control panel that a power supply

has failed. See the table on the

right for pin definitions.

Power Fail

Pin Definitions (JP9)

Pin

Number

1
2
3
4

Definition

P/S 1 Fail Signal
P/S 2 Fail Signal
P/S 3 Fail Signal

Reset (from MB)

Note: This feature is only available when

using redundant Supermicro power supplies.

SMB (I

2

C) Connector

An I

2

C connector at J11 (located

near the battery on the X6DHR-

8G2 and near the IPMI header on

the X6DHR-8G/X6DHR-X8G) moni-

tors the status of the PWR supply,

the fans and the system tempera-

ture.

SMB PWR

Pin Definitions (J27)

Pin #

1
2
3
4
5

Definition

Clock

SMB Data

N/A
N/A
N/A

Overheat LED (JOH1)

C o n n e c t a n L E D t o t h e J O H 1

h e a d e r t o p r o v i d e w a r n i n g o f

c h a s s i s o v e r h e a t i n g . S e e t h e

table on the right for pin defini-

tions.

Pin

Number

1
2

Definition

+5V

OH Active

Overheat LED

Pin Definitions (JOH1)

GLAN1/2 (Ethernet Ports)

Two gigabit Ethernet ports (desig-

nated GLAN1 and GLAN2) are lo-

cated on the I/O backplane. These

ports accept RJ45 type cables.

Advertising