System Fans

Two 10-cm blower fans provide all the cooling needed for the SuperServer

6014H-8/6014H-82/6014H-X8. It is very important that the chassis top cover

is properly installed and making a good seal in order for the cooling air to

circulate properly through the chassis and cool the components. See Fig-

ure 6-2.

The rpm of the blower fans can be adjusted with a setting in BIOS [see

page 7-17 - recommended setting is "3-pin (Server)"].

System Fan Failure

If a fan fails, the ambient air temperature in the chassis will rise and acti-

vate the Overheat/Fan Fail LED on the control panel. Replace any failed fan

immediately with the same type and model. You must power down the

system before replacing a cooling fan (removing the power cord is also

recommended as a safety precaution).

Replacing System Cooling Fans

1.

Removing a fan

After first turning off the power to the system, remove the chassis cover

and unplug the fan cable from the motherboard. Unscrew the failed

blower fan from the chassis and pull it completely out from the

serverboard.

2.

Installing a new fan

Replace the failed fan with an identical 10-cm, 12 volt fan (available from

Supermicro: p/n FAN-0059). Install the new fan in its proper place in the

chassis by positioning it on the two mounting posts. Secure the fan to

the chassis with the screws you removed previously, then attach the fan

wires to the same chassis fan header you removed it from. Make sure

the air seal under the fan is properly installed and creating a good seal.

Power up the system and check that the fan is working properly and that

the Overheat/Fan Fail LED on the control panel has turned off. Finish by

replacing the chassis cover.