1 central convergence, 2 convergence linearity, 3 convergence sizes – Sim2 Multimedia SVP 420 HB User Manual

Page 36: 4 convergence skew, 5 convergence bow, Englishenglishenglishenglishenglish

Advertising
background image

SVP 450 PLUS - SVD 500 PLUS

35

ENGLISHENGLISHENGLISHENGLISHENGLISH

CONV CENT

CRT : RGB
ADJ : R . .

H. = 52

V. = 50

b

b

a

a

CONV LIN

CRT : RGB
ADJ : R . .

H. = 45

V. = 50

5.13.1 Central convergence

This function allows to overlap the blue and red
images on the green one, at the centre of the screen.

Press CONV. The following menu will appear:

Use the buttons R,G, and B, to switch on/off the tubes.
The CRT message: RGB shows which tubes are on. Use
the buttons Rsel, Gsel, Bsel, to select on which tube you
wish to act. The ADJ message: R. indicates on which
tube you are acting. Press ENTER o EXIT to change
adjustment.
Press ESC to exit.

5.13.2 Convergence linearity

This function is used to modify the distance between
the cross hatch lines until they are equal.
Use the arrow or to change the vertical linearity, and

the arrow or for the horizontal one.

5.13.3 Convergence sizes

This function allows to re-size the image dimensions
for the blue and red CRTs.

CONV SIZE

CRT : RGB
ADJ : R . .

H. = 80

V. = 50

Use the R,G,B, buttons to switch on or off the tubes.
The CRT message: RGB indicates which tubes are
switched on. Use the Rsel, Gsel, Bsel, buttons to select
on which tube you wish to act. The ADJ message: R.
indicates on which tube you are acting. Press ENTER or
EXIT to change adjustment.
Press ESC to exit.

5.13.4 Convergence skew

This function allows to setup the transversal
horizontal and vertical inclination.

CONV SKEW

CRT : RGB
ADJ : R . .

H. = 48

V. = 50

Use the R,G,B, buttons to switch on or off the tubes.
The CRT message: RGB indicates which tubes are
switched on. Use the Rsel, Gsel, Bsel, buttons to select
tube you wish to act. The ADJ message: R. indicates on
which tube you are acting. Press ENTER or EXIT to
change adjustment.
Press ESC to exit.

5.13.5 Convergence bow

This function allows to setup the horizontal and
vertical curving.

CONV BOW

CRT : RGB
ADJ : R . .

H. = 52

V. = 50

Use the R,G,B, buttons to switch on or off the tubes.
The CRT message: RGB indicates which tubes are
switched on. Use the Rsel, Gsel, Bsel, buttons to select
tube you wish to act. The ADJ message: R. indicates on
which tube you are acting. Press ENTER or EXIT to
change adjustment.
Press ESC to exit.

Advertising
This manual is related to the following products: