12 troubleshooting – Sim2 Multimedia SVP 420 HB User Manual

Page 42

Advertising
background image

SVP 450 PLUS - SVD 500 PLUS

41

ENGLISHENGLISHENGLISHENGLISHENGLISH

12 TROUBLESHOOTING

The LED lights on the rear panel shows the projector status.

LED Lights

MEANING

ON indicator

Red light

Stand-by mode

Green light

Normal operation

Remote control

The projector is

indicator

Intermittent light

receiving a command
from remote control

In case of malfunction, before calling in a technician check the following table:

PROBLEM

The projector will not turn on

No picture is displayed on the screen

The picture is not properly displayed

on the screen

The message Fan Protection

Detected switch off in 06 seconds

appears on the screen

The message ERROR ON 12C-bus

board xxx device xxx

appears on the screen

The message Convergence

Overload Switch-Off in xxx seconds

appears on the screen

During normal operation the projector

switches off

CAUSES

The ON push button has not been

pressed

The power cable is disconnected

The projector is switched off

The input setting is wrong

The picture setup is wrong

One or more fans have stopped

A communication error has been

detected

Overcurrent has been detected

on the convergence board

The projector is in the

PROTECTION MODE

REMEDY

Press the ON button

Connect the power cable

If the LED is red it means the

projector is on stand-by. Press a

numerical key to switch it on.

Ref. INPUT SELECTION

Ref. PICTURE ADJUSTMENT

Check that the cooling fan ventilation

holes are not clogged

Switch the projector off and then back

on again. If the message persists

contact a qualified technician

Reset the current memory bank and

repeat installation.

If the message persists contact a

qualified technician

Ask for service

Advertising
This manual is related to the following products: