Sony PDW-F70 User Manual

Page 90

Advertising
background image

90

System Menu

Cha

p

te

r 6

Me

nu
s

TIME CODE [Time Code]: Settings related to the timecode
generator

Description

TCG REGEN [> TCG regen]: Select the signals to generate

when the timecode generator is set to regenerate mode
(TC MODE on page P2 of the function menu is set to
“REGEN”).

*

TC & UB [>> TC & UB]: Regenerate both timecode signals

and user bits signals.

TC [>> TC] :Regenerate timecode signals only.
UB [>> UB]: Regenerate user bits signals only.

UB BINARY GP. [> Binary Gp.]: Settings related to the user

bits binary group flag.

Note

When TCG on page P2 of the function menu is set to anything
other than “INT”, and TC MODE is set to “REGEN”, the user
bits binary flag setting of external timecode is followed.

*

000:NOT SPECIFIED [>> 000]: Character set not specified

001:ISO CHARACTER [>> 001]: 8-bit characters conforming

to ISO 646 and ISO 2022

010:UNASSIGNED-1 [>>010]: Undefined
011:UNASSIGNED-2 [>> 011]: Undefined
100:UNASSIGNED-3 [>> 100]: Undefined
101:PAGE/LINE [>> 101]: Multiplex
110:UNASSIGNED-4 [>> 110]: Undefined
111:UNASSIGNED-5 [>> 111]: Undefined

VITC POS SEL-1 [> VITC pos-1]: Select a line to insert the

VITC in.

Note

You can insert the VITC signal in two places. To insert it in two
places, set both this item and VITC POS SEL-2.

When the system frequency is 60i, 23.98P or 30P
20LINE [>> 20 line] to 12LINE [>> 12 line]: Select any line

from 12 to 20.

Factory default setting: *16 LINE [>> 16 line]

Note

When the system frequency is 60i, 23.98P, or 30P, the VBID
(Video Blanking ID) receives priority over a selection of
“20LINE”.

When the system frequency is 50i or 25P
22LINE [>> 22 line] to 9LINE [>> 9 line]: Select any line from

9 to 22.

Factory default setting: *19 LINE [>> 19 line] (line 19)

VITC POS SEL-2 [> VITC pos-2]: Select a line to insert the

VITC in.

Note

You can insert the VITC signal in two places. To insert it in two
places, set both this item and VITC POS SEL-1.

When the system frequency is 60i, 23.98P or 30P
20LINE [>> 20 line] to 12LINE [>> 12 line]: Select any line

from 12 to 20.

Factory default setting: *18 LINE [>> 18 line]

Note

When the system frequency is 60i, 23.98P, or 30P, the VBID
(Video Blanking ID) receives priority over a selection of
“20LINE”.

When the system frequency is 50i or 25P
22LINE [>> 22 line] to 9LINE [>> 9 line]: Select any line from

9 to 22.

Factory default setting: *21 LINE [>> 21 line] (line 21)

EE OUT PHASE [> EE out]: Determine the output phase for

the LTC signal output from the TIME CODE OUT
connector when recording timecode and in STOP REC
mode (forced E-E mode).

*

MUTING [>> muting]: Suppress the output.

THROUGH [>> through]: Output the timecode input to the

TIME CODE IN connector as it is.

VIDEO INPUT PHASE [>> V input]: Output the timecode with

the same phase as the input video signal phase.

VIDEO OUTPUT PHASE [>> V output]: Output the timecode

with the same phase as the output video signal phase.

SEARCH MUTING [> Srch muting]: Select whether to

suppress the output from the TIME CODE OUT connector
in search (jog/shuttle) mode.

OFF [>> OFF] : Do not suppress.
*

ON [>> ON]: Suppress.

PD PRESET [> PD preset]: Select the timecode to preset.

The A-frames of pulldown sequences are preset.

24F TC [>> 24F TC]: Timecode value that becomes the

reference for A-frames.

30F TC [>> 30F TC]: Pulldown value with respect to the above

24-frame timecode. This appears only when 24P (2-3
pulldown) is selected.

Advertising