4 fuction code description, 1 function code description format – Seiko Instruments DPU-30 User Manual

Page 34

Advertising
background image

5-6

• The second byte

00

16

through 1F

16

: The first byte already entered is ignored. Function codes are processed

as function codes. All the other codes are ignored along with the first
byte. If the following code accompanies a Kanji mode clear command,
the next received data is processed as a 1-byte character code.

20

16

:

Ignored along with the first byte.

21

16

through 7E

16

: Print Kanji or user-defined characters if the first byte is one of 21

16

through 7E

16

.

7F

16

:

Ignored along with the first byte.

80

16

through FE

16

: Ignored along with the first byte unless the first byte is 00

16

.

FF

16

:

Ignored along with the first byte.


For the correspondence between the 2-byte codes and the printed characters, refer to “Kanji Code
Table” (as per JIS C 6226-1983).


5.4 FUNCTION CODE DESCRIPTION

This chapter describes the commands in each function by the mode.

5.4.1 Function Code Description Format

Each function code is described in the format below.
The same format is used for both Mode 1/Mode 2 and Mode 3.

X X

X

X

X

X

Indicates

the command.

Indicates

the command name.

Code

Indicates command part and parameter past.

X

16

indicates hexadecimal code.

Function Indicates the functions of the commands.

Details

Explains detailed printer operation when inputting commands.