5-34

8. Response commands (only for serial mode)

GS a n

Validity / Invalidity of Automatic Status Transmission and Real Time Command Select

Code

1D

16

+ 61

16

+ n

Domain of

function

0

≤ n ≤ 3

Function

Specifies the validity or invalidity of the automatic status response which is one of
the printer statuses.
Specifies the validity or invalidity of the real time command.
n

= 0: The automatic status response becomes invalid.

n

= 1: The automatic status response becomes valid. And the current status is

returned.

n

= 2: The real time command becomes invalid.

n

= 3: The real time command becomes valid

Details

• The automatic status response automatically returns a response depending on

the change in status.

• The real time command is executed at the reception.
• For the status values, refer to Table 5-1 Status Response Value Table.
• This command is executed at the deployment of the receive buffer so that the

execution of the command may be delayed depending on the conditions of the
receive buffer.

• When a value is returned, the conditions of the host computer are not checked.
• In default, both the automatic status response and the real time command are

invalid.