5-8

SI

Double–Width Printing Mode Clear

Code

0F

16

Function

Clears the double

−width printing.


CAN Cancel

Code

18

16

Function

Clears the print buffer.

Details

• After executing this command, a head of a line is set as a starting position of

printing.


ESC S n1 n2 n3 n4 Bitimage

Graphic

Code

1B

16

+ 53

16

+ n1 + n2 + n3 + n4 + [DATA]

Domain of

function

30

16

≤ n1, n2, n3, n4 ≤ 39

16

“0001”

≤ “n1 n2 n3 n4” ≤ “1023”

0

≤ d ≤ 255 (graphic data)

Function

The number of data specified in ASCII code n1, n2, n3 and n4 are specified as a
Bitimage.
Example: Case that 192 Bitimages are specified

1B

16

+ 53

16

+ “0192” + . . . . . . . . .

[192 DATA]

Details

• The code outside the domain of function processes the data as the 1-byte data

thereafter.

• If the dots are specified outside the printing area, the data is ignored.
• The data deployment position is set in accordance with the predefined starting

position of the data deployment.

• This command is affected by the inverse printing.
• If the next Bitimage Specify command is received at the occurrence of the line

overflow, the data of the previous line stored in the print buffer is printed. The line
overflow is determined according to the number of dots described below.

− Mode 1: Determined as the line overflow if the number of dots exceeds 276.

− Mode 2: Determined as the line overflow if the number of dots exceeds 332.

• Refer to the figure shown below for how the data is deployed.