Seiko Instruments DPU-30 User Manual

Page 43

Advertising
background image

5-15

2. Tab

commands

HT Horizontal

Tab

Code

09

16

Function

Moves the printing position to the position of the next horizontal tab.

Details

• If the position of the horizontal tab is not set, this command is ignored.
• If the position of the horizontal tab is out of the printing area, it is set at the head

of the next line.

• The position of the horizontal tab is set using the ESC D command.
• The default value of the horizontal tab is 8 character pitches.


ESC D n1...nk NUL

Horizontal Tab Set

Code

1B

16

+ 44

16

+ n1...nk + 00

16

Domain of

function

1

≤ n ≤ 255

0

≤ k ≤ 32

Function

Sets the position of the horizontal tab.
n describes the number of characters from the head of a line to the position at
which the horizontal tab is set.
k describes the number of data to be set.

Details

• The position of the horizontal tab to be set is [character width × n].
→ The character width includes the right space and the horizontal scaling factor.
• All the values previously set are cleared.
• The maximum number of horizontal tab positions settable is 32. If the number

exceeds the limit, the rest of the data is processed as normal data.

• The positions are set in ascending order. And the final value is NUL code.
• If the smaller value is set than previously set value, such value is recognized as

NUL code.

• Even if changing the width of character after setting, the position of tab set is not

changed.


Advertising