Seiko Instruments DPU-30 User Manual

Page 49

Advertising
background image

5-21

ESC – n

Underline Specify and Clear

Code

1B

16

+ 2D

16

+ n

Domain of

function

0

≤ n ≤ 255

Function

Specifies and clears the underline.

n

= <xxxxx000>B: underline 0 dot pitch


n

= <xxxxx111>B: underline 7 dot pitch

Details

• n is valid only for the low 3 bits.
• This setting is valid only for the standard size characters.
• The underline is added to the width of character and the character spacing.
• This function is not affected by the setting of the amount of line specing.
• If the several underlines with the different thicknesses exist in one line, the

thickness of those underlines will be brought into line with the thickest underline.

• In default, n = 0.


GS ! n

Character Size Set

Code

1D

16

+ 21

16

+ n

Domain of

function

0

≤ n ≤ 255

Function

Specifies the character size.

n

= <xxxx0000>B: scaling factor in the vertical direction : × 1 <minimum>


n

= <xxxx0111>B: scaling factor in the vertical direction : × 8 <maximum>


n

= <0000xxxx>B: scaling factor in the horizontal direction : × 1 <minimum>


n

= <0111xxxx>B: scaling factor in the horizontal direction : × 8 <maximum>

Details

• This setting is valid for any type of characters other than HRI characters.
• n is valid only for 0 to 2 bits and 4 to 6 bits.
• In default, n = 0.


Advertising