Seiko Instruments DPU-30 User Manual

Page 60

Advertising
background image

5-32

DC3 D nl nh

Write in Position Specified by Dot in Ruled Line Buffer

Code

13

16

+ 44

16

+ nl + nh

Domain of

function

0

≤ nl ≤ 255

0

≤ nh ≤ 3

Function

Writes 1 in the specified position in the ruled line buffer.

The position is set at [(nh × 256 + nl) × dot pitch].

Details

• Regardless of the printable area, this function writes 1 in the selected ruled line

buffer.

• nh is valid only for the low 2 bits.


DC3 L nl nh ml mh

Write in Position Specified by Line in Ruled Line Buffer

Code

13

16

+ 4C

16

+ nl + nh + ml + mh

Domain of

function

0

≤ nl ≤ 255

0

≤ nh ≤ 3

0

≤ ml ≤ 255

0

≤ mh ≤ 3

Function

Writes 1 in the range from nhnl to mhml in the ruled line buffer.
0

≤ nhnl ≤ mhml ≤ 1023

nhnl

= (nh × 256 + nl) × dot pitch

mhml

= (mh × 256 + ml) × dot pitch

Details

• Regardless of the printable area, this function writes 1 in the selected ruled line

buffer.

• nh and mh are valid only for the low 2 bits.


Advertising