Instllation of sensor amp – Sierra Monitor Corporation IZS31 User Manual

Page 10

Advertising
background image

9


„ Auto balance sensor

Horizontally place the auto balance sensor under the ionizer and face its metal plate upward. Because

the ion balance will be changed depending on the installation height, install the sensor on the same level
with a workpiece as much as possible. The auto balance sensor can be removed once the ion balance
adjustment is completed.

Keep the height between the auto balance sensor and ionizer within the installation height stated in

2-1.

Mount the head sensor with 2 pieces of M3 screws (sold separately).


2. Installation of sensor amp

A sensor amp should be mounted with 2 pieces of M3 screws (sold separately).
Do not pull a cable out of the sensor amp. If the cable is pulled with a strong force, the sensor amp might

be damaged or its wires might be broken.

Be sure to ground the sensor amp case. (Resistance between the sensor amp case and the earth

ground should be 100Ω or less.) Because the sensor amp case surface is treated with conductive
plating, FG wiring is not necessary when the sensor amp case is connected to the mounting surface of the
grounded unit. If the mounting surface is insulated with painting or being anodized, be sure to connect the
FG wiring for grounding.



















2-3. Connection of cable


1. Insert the modular plug of power supply cable IZS31-CP

into the modular jack for indicating [power] on the ionizer
body. A lever will snap when the modular plug is correctly
locked

.

Fix cables with a tie wrap or other measures in the

vicinity of connection not to apply compulsive force to the
modular jack and plug.

Metal plate

M3 threads

Head side

Class D ground

Sensor

Advertising