Alarm/timing chart, 15 9. alarm – Sierra Monitor Corporation IZS31 User Manual

Page 16

Advertising
background image

15

9. Alarm

Type of alarm

Description

How to reset

Abnormal high voltage

Notifies when overcurrent such as high voltage
leakage occurs. The ion-discharge-output is
stopped, HV ALRM sets off and output the
signal for failure.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

Sensor failure

Notifies that the feed back sensor doesn’t work
properly. SNSR ALARM lights up, and the

signal for sensor failure is output.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

CPU failure

Notifies that CPU fails due to noise. All LEDs
Flashes, and the signal for CPU failure is
output.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

Electrode needle
maintenance

Notifies when the maintenance of the electrode

needle is necessary. NDL CHECK ALARM
lights up, and the maintenance output signal is
output.

Turn off the power supply and clean the
electrode needle. Then apply the power
supply.

10. Timing chart

„ Timing chart with a normal operation


















„ Timing chart when the dirt on the electrode needle is detected


















・The completion signal for static charge elimination is output while the dirt on the electrode needle is being detected

・Because ions are discharged from the ionizer when the electrode needle is being detected, the workpiece might be charged.
Therefore, the workpieces should not be mounted when the detection is executed.

ON and OFF status will be changed depending on the situation

ON

Input

OFF

ON

OFF

ON

Output

OFF

ON (SW ON)

Input

OFF

ON (SW ON)

Output

OFF

ON

(LED)

Blink

LED

OFF

Power supply
DC24V

Discharge stop
signal

Maintenance indication

(With NDL CHECK ALARM)

Completion signal for
Static charge

Maintenance
start-up signal

Maintenance
output signal

Contamination detecting of electrode

100ms or more

2s

30V

0V

ON

Input

OFF

ON

(Opration)

OFF

ON

(discharge)

OFF

ON

(Output)

OFF

ON

(LED)

LED

OFF

Sensor monitor output

Charged condition

(with ION LED)

Charged condition of the work

Power supply DC24V

Discharge-stop signal

Completion signal for
static charge elimination

Input

Output

Output

Input

(discharge)

(Operation)

Advertising