Led display/alarm – Sierra Monitor Corporation IZS31 User Manual

Page 22

Advertising
background image

21


6. LED display

„ POWER LED ・・・ The power supply input and the connection of the sensors are displayed.





LED name

Functions

MAIN

Lights up when the power supply is applied. (Green)
(Flashes when wrong power supply is applied. )

POWER

SNSR Goes

out.

„ ION LED ・・・ The discharged ion polarity is displayed.





LED name

Functions

Lights on when plus ions are generated.(Orange)

OK Goes

out.

ION

Lights on when minus ions are generated.(Blue)


„ ALARM LED ・・・ Failure of the ionizer is displayed.




LED name

Functions

HV

Lights up when overcurrent is applied to the electrode needle. (Red)

SNSR Goes

out.

ALARM

NDL
CHECK

Goes out.

7. Alarm

Type of alarm

Description

How to reset

Abnormal high voltage

Notifies when overcurrent such as high voltage
leakage occurs. The ion-discharge-output is
stopped, HV ALRM sets off and output the
signal for failure.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

CPU failure

Notifies that CPU fails due to noise. All LEDs
Flashes, and the signal for CPU failure is
output.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

8. Timing chart

„ Timing chart with a normal operation






ON

Input

OFF

ON

(Operation)

Input

OFF

ON

(Discharge)

OFF

Power supply DC24V

Discharge-stop signal

State of ion discharge

Advertising