8. LED display

„ POWER LED ・・・ The power supply input and the connection of the sensors are displayed.





LED name

Functions

MAIN

Lights up when the power supply is applied. (Green)
(Flashes when wrong power supply is applied.)

POWER

SNSR

Lights up when the feed back sensor is connected.(Green)

„ ION LED ・・・ The charged condition of the work is displayed.





LED name

Functions

The charged potential of the work is positive.(Orange)

OK

The charged potential of the work is low.(Green)

ION

The charge potential of the work is negative.(Blue)

・The charged condition of the work can be identified with the LED display.















„ ALARM LED ・・・ Failure of the ionizer is displayed.






LED name

Functions

HV

Lights up when overcurrent is applied to the electrode
needle.(Red)

SNSR

Lights up when the feed back sensor doesn’t work properly.
(Red)

ALARM

NDL
CHECK

Lights up when dirt on the electrode needle is detected.
(Red)
(Flashes when the dirt is being detected. )


Charged polarity of work

LED

+

OK

-

Charged potential of the work

Plus

■□□

More than +400V

light on

□□

+100V to +400V

flash with 4 Hz

■□

+30V to +100V

light out

static charge elimination

□■□

+30V to -30V

□■

-30 to -100V

□□

-100 to -400V

Minus

□□■

More than -400V