Sensor, Sensor output voltage v – Sierra Monitor Corporation IZS31 User Manual

Page 26

Advertising
background image

25

5-2Sensor

Sensor model

IZS31-DF

(Feed back sensor)

IZS31-DG

(Auto-balance sensor)

Operating ambient temp

0 to 50 ℃

Operating ambient humidity

35 to 80%Rh(No dew condensation)

Case material

ABS

ABS, Stainless

Vibration resistance

Endurance 50Hz, Amplitude 1mm, 2hours each for XYZ

Impact resistance

10G

Weight

200g(including cable weight)

220g(including cable weight)

Installation distance

10 to 50mm (Recommended)

-

Applicable standard/ directive

CE (EMC directive:89/336/EEC,92/31/EEC,93/68/EEC,2004/108/EC、

Low voltage directive:73/23/EEC,93/68/EEC)




„

Sensor monitor output (When feed back sensor is used)




























„ Detection range of Feedback sensor









Installation

distance mm

Detection range

mm

10 45
25 100
50 180

Relation of sensor output and charge potential based pm

installation distance

0

1

2

3

4

5

6

-2000

-1500

-1000

-500

0

500

1000

1500

2000

Charge potential V

Sensor output voltage V

Installation distance
25mm

Installation distance
25mm

Installation distance
10mm

Sensor head

Detection hole

Installatio

n distance

Detection range

Advertising