4-3DC mode

1. Selection of bar length

・Select the length applicable to work size base on static charge elimination area and static charge

elimination characteristics.

2. Installation of body

・Keep the distance between the ionizer and charged objects within 50 to 2000mm. Although the ionizer

can be mounted outside of this range, it may not operate properly depending on the operating conditions.
Therefore, be sure to check if the ionizer will operate properly.


3. Installation of the sensor

・[Plus ion discharge] or [minus ion discharge] can be selected.

Ion polarity

Switch setting

Plus ion discharge

8

Minus ion discharge

9

4. Wiring of the power supply cable

・Connect dedicated power supply cables.

„ Connection with the power supply for ionizer operation

Symbol Cable

color

Cable name

Connection

Description

DC1(+)

Brown Power

supply

DC24V

DC1(-)

Blue Power

supply

GND[FG]

Power supply cable for
ionizer operation

OUT4 Dark

Green

Sensor monitor output

※ Be sure to ground DC1(-)[Blue].(Resistance between the lead wire and the earth ground should be 100Ωor less.)
If not, it may break the ionizer.

„ Connection with the power supply for I/O signal

Symbol Cable

color

Cable name

Connection

Description

DC2(+)

Red Power

supply

DC24V

DC2(-)

Black Power

supply

GND

Power supply cable for I/O signal

IN1 Light

Green

Discharge-stop signal

Signal for starting/ stopping the discharge
(NPN spec)Operation will begin when it is connected
with DC2(-)[Black].
(PNP spec)Operation will begin when it is connected
with DC2(+)[Red].

IN2 Gray

Maintenance

start-up

signal

White

Orange

OUT1 Pink

Completion signal for
static charge elimination

OUT2 Yellow

Maintenance

output

signal

OUT3 Purple

Signal for failure

Outputs in case of abnormal high voltage and sensor
and/or CPU failure.
(B contact output)

○ : Wires that are minimum required to operate the ionizer.
△ : Wires that are required to use the functions.
- : Wires that are not necessary with the sensing DC mode. These wires should not be short-circuited with other

cables.

5. Air piping

・When the piping is only connected to one port, the other unused port should be plugged with the M-5P
that is packaged together with the ionizer.