Setting of the frequency selecting switch – Sierra Monitor Corporation IZS31 User Manual

Page 18

Advertising
background image

17

5. Setting of the frequency selecting switch

・Select the ion-production frequency.

Ion-production

frequency

Switch setting

1Hz 0
3Hz 1
5Hz 2

10Hz

3

15Hz 4
20Hz 5
30Hz 6
60Hz 7

6. Wiring of the power supply cables

・Connect a dedicated power supply cable.

„ Connection power supply for ionizer drive

No Lead

wire

color

Description

Direction

of signal

Function

DC1(+)

Brown Power

supply

DC24V

DC1(-)

Blue Power

supply

GND[FG]

power supply cable for
ionizer drive

OUT4

Dark Green

Sensor monitor
output

※ Be sure to ground DC1(-)[Blue]. (Resistance between the lead wire and the earth ground should be 100Ω or less.)
If not, it may break the ionizer.

„ Connection power supply for I/O signal

No Lead

wire

color

Description

Direction

of signal

Function

DC2(+)

Red Power

supply

DC24V

DC2(-)

Black Power

supply

GND

Power supply cable for I/O signal

IN1 Light

Green

Discharge-stop signal

Signal for starting/ stopping the discharge
(NPN spec)Operation will begin when it is
connected with DC2(-)[Black].
(PNP spec)Operation will begin when it is
connected with DC2(+)[Red].

IN2 Gray

Maintenance

start-up

signal

A signal that is input when the maintenance of the
electrode needle is necessary.

White

Orange

OUT1 Pink

Completion signal for
static charge elimination

Outputs when the dirt on the electrode needle is
detected.

OUT2 Yellow

Maintenance

output

signal

Outputs when the maintenance of the electrode
needle is necessary.

OUT3 Purple

Signal for failure

Outputs in case of abnormal high voltage and
sensor and/or CPU failure.
(B contact output)

○ : Wires that are minimum required to operate the ionizer.
△ : Wires that are required to use the functions.
- : Wires that are not necessary with the pulse DC mode. These wires should not be short-circuited with other cables.


7. Air piping

・When the piping is only connected to one port, the other unused port should be plugged with the M-5P
that is packaged together with the ionizer.


DC Power supply

Brown

Blue

Ground