24

5.Specifications


5-1 Ionizer

Ionizer model

IZS31(NPN)

IZS31P(PNP)

Type

Corona discharge

Voltage supply method

Sensing DC, pulse DC, Plus DC, Minus DC

Discharge output

+/- 7000 V

Ion balance *1

+/-30V (For Stainless electrode needle, from -100 to +100V)

Fluid

Air (Clean dry air)

Op. pressure

(MPa)

0.7 MPa or less

Purge air

Connection

tube size

Φ4

Power supply voltage

DC24 V + / - 10 %

Sensing DC mode operated

200 mA or less (When sensor is standby:120 mA or less)

Sensing DC mode stand-by

200 mA or less (When sensor is not used:170 mA or less)

Current consumption

Pulse DC mode

170mA or less

Discharge stop signal

Input signal

Maintenance start-up

signal

No-voltage contact signal

Completion signal for

static charge elimination

Maintenance output signal

Signal for failure

Maximum load current : 100mA

Residual voltage : 1V or less

(when the load current is 100mA)

Max. applied voltage:DC28V

Maximum
load current : 100 mA
Residual voltage : 1V or less

(With load current of 100 mA)

Output signal

Sensor monitor output

*2

Output voltage: 1 to 5 V (Please connect the load of 10kΩ or more.)

Effective elimination distance

50 to 2000 mm (with sensing DC mode:200 to 2000 mm)

Ambient temperature

0 to 50 ℃

Ambient humidity

35 to 80 %Rh(No dew condensation)

Material

Ionizer cover:ABS

Electrode needle:Tungsten, single crystal silicon, stainless

Vibration resistance

Endurance 50Hz Amplitude 1mm

2 hours to X,Y,Z each direction of vibration

Impact resistance

10G

Applicable standard/ directive

CE (EMC directive:89/336/EEC,92/31/EEC,93/68/EEC,2004/108/EC、

Low Voltage Directive:73/23/EEC,93/68/EEC)

※1:The distance between the charged object and ionizer is 300mm or more. With air purge.
※2:When the potential of the charged object is measured with the feed back sensor, the relation

between the charged potential and the sensor-monitor-output-voltage and the sensor detecting
range will vary depending on the installation distance between the ionizer and sensor.



[Electrode cartridge quantity and weight]

Bar length mm

300 380 620 780 1100 1260 1500 1900 2300

Q’ty of electrode
cartridge

3 4 7 9 13 15 18 23 28

Weight g

330 400 600 720 1000 1100 1500 2000 2500