Alarm/timing chart, 19 9. alarm, Manual operation – Sierra Monitor Corporation IZS31 User Manual

Page 20: Auto operation

Advertising
background image

19

9. Alarm

Type of alarm

Description

How to reset

Abnormal high voltage

Notifies when overcurrent such as high voltage
leakage occurs.The ion-discharge-output is
stopped, HV ALRM sets off and output the signal
for failure.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

Sensor failure

Notifies that the auto balance sensor doesn’t
work properly. SNSR ALARM lights up, and the
signal for sensor failure is output.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

CPU failure

Notifies that CPU fails due to noise. All LEDs
Flashes, and the signal for CPU failure is output.

Turn off the power supply to solve the problem.
Once it’s solved, apply the power supply again.
Or turn on and off the discharge-stop signal.

Electrode needle
maintenance

Notifies when the maintenance of the electrode
needle is necessary. NDL CHECK ALARM lights
up, and the maintenance output signal is output.

Turn off the power supply and clean the
electrode needle. Then apply the power supply.

10. Timing chart

„ Timing chart with a normal operation






„ Timing chart when the dirt on the electrode needle is detected

adjust ion balance

(a)With auto balance sensor















(b)W/o auto balance sensor














・The completion signal for static charge elimination is output while the dirt on the electrode needle is being detected

・Because ions are discharged from the ionizer when the electrode needle is being detected, the workpiece might be charged.
Therefore, the workpieces should not be mounted when the detection is executed.




Contamination detecting
of electrode needle

Adjust ion balance

Ionizer
operation

ON

Input

OFF

ON (Operation)

Input

OFF

ON (Discharge)

OFF

Power supply DC24V

Discharge-stop signal

State of ion discharge

Manual operation

ON

Input

OFF

ON

Input

OFF

ON

(Contamination detecting of electrode needle / Ion balance is being adjusted.)

Output

OFF

ON

(SW ON)

Input

OFF

ON

(SW ON)

Output

OFF

ON

(Lighting)

Blink

LED

OFF

Power supply DC24V

Discharge-stop signal

Maintenance indication

(NDL CHECK ALARM)

Completion signal for
Static charge elimination

Maintenance
Start-up signal

Maintenance
Output signal

2s

100ms or more

② Auto operation

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

LED

OFF

(NDL CHECK ALARM)

100ms or more

2s

Power supply DC24V

Discharge-stop signal

Completion signal for
Static charge elimination

Maintenance
Start-up signal

Maintenance
Output signal

Maintenance indication

Input

Output

Output

Input

Input

ON

Input

OFF

ON

Input

OFF

ON

Output

OFF

ON

(SW ON)

Input

OFF

ON

(SW ON)

Output

OFF

ON

(Lighting)

Blink

LED

OFF

(NDL CHECK ALARM)

ON and OFF status will be changed depending on the situation

.

100ms or more

2s

行)

Maintenance indication

Maintenance
Output signal

Maintenance
Start-up signal

Completion signal for
Static charge elimination

Discharge-stop signal

Power supply DC24V

(Operation)

Detection is executed when the
maintenance level selecting switch,

H, M or L is selected

.

Contamination detecting
of electrode needle

Adjust ion balance

Ionizer
operation

Detection is executed when the
maintenance level selecting switch,
H, M or L is selected

.

(Contamination detecting of electrode needle)

(Operation)

Contamination detecting
of electrode needle

Adjust ion balance

Ionizer
operation

Detection is executed when the
maintenance level selecting switch,

H, M or L is selected

.

(Contamination detecting of electrode needle)

(SW ON)

(SW ON)

(Lighting)

(Operation)

Blink

Advertising