S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

Technical Training Department

State Water Heaters

STC-077

18

Ashland City, Tennessee © 2004

TROUBLESHOOTING

PRE-SERVICE TIPS

SUF SERVICE HANDBOOK

120 VAC TO CONTROL

STEP 1: CHECK FOR 120 VAC TO CONTROL BOARD CN1 TERMINAL.
Condition:

• Disconnect plug from CN1 terminal.
• On/Off switch is on.

Check for 120 VAC black wire terminal white wire on plug.

STEP 1

120 VAC TO CONTROL BOARD

IF…

THEN

120 VAC is not present

check On/Off switch, turn switch on, replace On/Off switch if defective, restore
power to the water heater.

120 VAC is present

reconnect CN1 plug, continue to Step 2.

CHECK THAT:

• Insure 120 VAC power supply has correct polarity — check neutral

(white) wire to ground with volt meter. It should read “0” volts.

• Tank is full of water
• Exhaust and intake vent do not exceed allowable limits
• All plugs into boards are secure
• Condensate hose is drained and open
• Proper (natural or propane) gas is supplied

STC-077