S U F S E R V I C E H A N D B O O K

S E R V I C E C H E C K L I S T

Technical Training Department

State Water Heaters

STC-077

40

Ashland City, Tennessee © 2004

SERVICE CHECKLIST

This is not intended to be and all-inclusive list of the problem that the Service Agent may encounter. Any item checked “no” on
this list should be thoroughly investigated and corrective action taken, if required.

SERVICE AGENT:

INSTALLATION DATE:

MODEL NUMBER:

SERVICE DATE:

SERIAL NUMBER:

LOCATION ADDRESS:
PHONE

( )

-

GAS

TYPE — CHECK ONE

NATURAL

PROPANE

PROPER GAS VALUE VERIFIED

YES

NO

I.

CHECK CLEARANCE (CIRCLE ANSWER)
A.

Are exterior clearances adequate?

yes

no

B.

Are interior clearances adequate?

yes

no

Comments:

II.

CHECK MAKEUP AIR REQUIREMENTS
A.

Is the quality of make-up air adequate?

yes no

Comments:

B.

Is the quantity of make-up air adequate?

yes

no

Comments:

III. GAS PRESSURE (FILL IN BLANK) — ALL UNITS ON.

A.

Supply gas pressure __ inches of W.C. (flowing)

B.

Manifold gas pressure (main burner) __ inches of W.C. (flowing)

Comments:

IV. VENTING (CHECK)

A.

Acceptable equivalent footage

yes

no

B.

Proper material

yes

no

C.

Proper exterior installation

yes

no

D.

Condensate will drain

yes

no

Comments:

V.

WATER PIPING
Is the system properly sized?

yes

no

Is the system properly installed?

yes

no

Are there any water leaks?

yes

no

Does the installation have a recirculating system?

yes

no

If so, is it operational?

yes

no

VI. SAFETY

A.

Air
If exhaust is blocked will unit lockout?
If air intake is blocked will unit lockout?

yes

no

yes

no

B.

Water Temperature
- Is the thermostat adjusted to the lowest acceptable temperature?

yes

no

- Does the installation have a mixing valve?

yes

no

- If so, is it operational?

yes

no

- What is the outlet temperature of the mixing valve?

yes

no

NOTE: To minimize the risk of scalding, the manufacturer recommends storing water at 120° F.

Is a properly rated temperature and pressure relief valve installed?

yes

no

Is there a properly installed expansion tank?

yes

no

Should there be?

yes

no

C.

Electrical
Is the 120 VAC electrical powers supply properly wired? (including polarity)

yes

no

Are all the SUF control covers in place?

yes

no

Is the 120 VAC electrical power supply properly fused?

yes

no

D.

Flammables
Are flammable materials located in the area of the water heater? or air intake?

yes

no

Are flammable vapors located in the area of the water heater? or air intake?

yes

no

E.

Gas
If the gas supply is reduced or turned off will the unit turn off?

yes

no

Comments:

[This service checklist may be photo copied to assist with SUF service calls.]