Ignitor resistance, Step 11 ignitor resistance check – State Industries Utra-Force STC-077 User Manual

Page 30

Advertising
background image

S U F S E R V I C E H A N D B O O K

T R O U B L E S H O O T I N G

State Water Heaters

Technical Training Department

Ashland City, Tennessee © 2004

29

STC-077

IGNITOR RESISTANCE

STEP 11: CHECK RESISTANCE BETWEEN TWO WIRE CONNECTS AT CN5 IGNITOR PLUG
END.
Condition:

• On/Off switch is off.
• Disconnect CN5 ignitor plug from circuit board.
• Multimeter is set to lowest ohms scale above 300 ohms.

STEP 11

IGNITOR RESISTANCE CHECK

IF…

THEN

ohms reading taken is not between 50 – 300 ohms

replace the ignitor.

ohms reading taken is between 50 – 300 ohms

reconnect CN5 plug, continue to Step 12.

Advertising